Project Name
Project Number
TEMF
Statement of Work
UFC 4-214-02, 24 Jul 03
Administration Area and Direct Exchange / Technical Support (DX/TX) areas. Bays shall be
single-story, ground floor spaces, without interior columns; minimum eave height shall be 5500
mm. [Minimum bay depth shall be 19 600 mm deep] [Review FPS planning data and coordinate
with user. If it is important to provide warehouse bay modules the same size as the repair bay
modules (and, provided the required area fits evenly into a given number of modules), delete
the previous sentence, retain the next sentence and insert the number of bays to be provided. It
is preferable to state minimum bay depth and area, and allow offeror flexibility of warehouse bay
width]. [Required area shall consist of [__] bay modules 9800 mm wide (column centerline to
column centerline) x 19 600 mm deep (exterior face of column to exterior face of column)].
[Insert any requirements for floor flatness tolerance in Warehouse Bay areas]
Warehouse Areas. Provide one [or more] area[s]; total net area shall be [____] m2.
2-2.3.1
Total occupants: [__]. [Refer to FPS for authorized area requirements]. Provide below grade
loading dock with [____] 3000 mm wide x 2900 mm high overhead doors. Loading dock shall
accommodate the following vehicle types: [insert vehicle data]. [In addition to loading dock
overhead doors, provide one 3000 mm wide x 2900 mm high overhead door per warehouse
bay; doors shall open to hardstand vehicle access surrounding the building] [Previous sentence
may be included as an optional item, additional doors will increase flexibility of warehouse
space]. Provide daylighting through use of metal windows or translucent wall panels at exterior
wall area above overhead door level. Occupants will use [insert vehicle type, method of
propulsion, load rating, wheel type, reach height] to store and retrieve items from storage
shelving.
2-2.3.1.1 Function: Storage of [insert types of materials; include hazard/flammability
classifications, methods of storage, height of racks or shelves, and other data the offeror will
need to establish applicable code requirements].
2-2.3.1.2 Adjacency requirements: Adjacent to DX/TS Area, Supply/Admin Area, and core
areas. Adjacent to hardstand vehicle access aisles.
2-2.3.1.3 Furnishings/Fixtures/Equipment: [Provide, and] design space to accommodate the
following storage systems: [insert types, quantities, dimensions, and load capacities of shelving,
pallet racks, bins, etc. Coordinate with user. Storage systems can be included in the
construction contract ]. Minimum clear aisle width between storage units shall be [3000 mm]
[verify with user].
Floor: concrete slab with sealer-hardener
Base: none
Interior side of exterior walls: painted concrete masonry units or painted concrete to overhead
door head height; prefinished metal liner panels above [CMU is recommended for durability. If
required due to budget constraints, metal liner panels may be used full height of interior face of
exterior walls; this also may be considered as an optional bid item]. Exposed structure shall be
painted.
Ceiling: prefinished metal liner panels on underside of roof purlins; exposed structure shall be
painted.
2-2.3.1.5 Other requirements: Provide 300 mm diameter x 1400 mm high, concrete-filled,
schedule 80 galvanized steel, pipe bollards inside the bay at each overhead door jamb, except
at loading dock doors (refer to Chapter 3 for exterior pipe bollards). Provide similar bollards at
interior locations as required to protect structural columns and other elements from damage.
SOW-32