Project Name
Project Number
TEMF
Statement of Work
UFC 4-214-02, 24 Jul 03
2-2.2.22.3 Furnishings/Fixtures/Equipment: As required by Statement of Work.
2-2.2.22.4 Finishes: Floor: sealed concrete
Base: resilient cove base
Walls: painted gypsum wallboard or painted concrete masonry units
Ceiling: none required.
2-2.2.22.5 Other requirements:
2-2.2.23
Elevator. Provide one hydraulic [passenger] elevator in each two-story building.
2-2.2.23.1 Function: Vertical conveyance of people and furniture.
2-2.2.23.2 Adjacency requirements: Adjacent to corridor; near main entry.
2-2.2.23.3 Furnishings/Fixtures/Equipment: [Passenger elevator: 2,500 lb. capacity, minimum
75 feet per minute speed; center opening doors.] [Elevator is required for handicapped
accessibility to second floor. If elevator will also be used to regularly move equipment between
shop areas, adjust the requirements of this paragraph to provide a freight elevator; retain
handicapped accessibility requirements.] Refer to Chapter 5 for additional requirements.
Walls: [plastic laminate]
Ceiling: [suspended aluminum egg crate]
Car door and front: satin finish stainless steel
Hoistway entrance doors and frame: satin finish stainless steel
2-2.2.23.5 Other requirements: Handicapped accessible.
2-2.2.24 Janitor Closet. Provide one at each group of toilets on each floor of the building.
Minimum area: 2.8 m2. Room shall be accessed from the corridor.
2-2.2.24.1 Function: Sink and storage of cleaning supplies, soap, paper products.
2-2.2.24.2 Adjacency requirements: Near toilets and shower rooms.
2-2.2.24.3 Furnishings/Fixtures/Equipment: Provide one floor mounted mop sink, mop rack for
two mops, and minimum 1829 linear mm of wall mounted stainless steel shelving.
2-2.2.24.4 Finishes:
Floor: sealed concrete
Base: resilient cove base, or ceramic tile base
Walls: painted water-resistant gypsum wallboard, or painted concrete masonry units
Ceiling: painted gypsum soffit board, or painted Portland cement plaster; minimum ceiling height
2800 mm.
2-2.2.24.5 Other requirements:
2-2.3
Warehouse Bay Areas. Warehouse bay areas are used for storage and issue of
supplies and equipment for an organization having a tech supply mission that provides DS or
GS level maintenance support. Warehouse Bay areas include Warehouse Area, Supply
SOW-31