Project Name
Project Number
TEMF
Statement of Work
UFC 4-214-02, 24 Jul 03
2
minimum net area shall be 28 m . Minimum dimensions shall be 4000 mm x 7000 mm. Total
occupants: [__] [one Weapons/Communications Security (COMSEC) Vault is authorized per
organization; minimum dimensions should be between 24 m2 and 28 m2. Organizations
requiring greater than 1,000 m2 of maintenance building are also authorized one COMSEC
Vault with a net area of 28 m2. When COMSEC Vault is authorized, delete "COMSEC" from this
paragraph, and add the following COMSEC Vault paragraph]. Provide GSA approved Class 5
vault door [with day gate] between Weapons Storage Vault and core Corridor. Walls, floor and
ceiling of Vault shall be concrete masonry or concrete; and all openings and penetrations shall
be constructed in compliance with [TI 800-01 Design Criteria and AR 190-11 Physical Security
2-2.2.16.1 Function: Secure storage of weapons being repaired, especially vehicle-mounted
weapons such as machine guns and firing port weapons. [It will also be used to store secure
communications equipment] [retain previous sentence if combined Weapons/COMSEC Vault is
to be provided].
2-2.2.16.2 Adjacency requirements: Adjacent to Corridor.
2-2.2.16.3 Furnishings/Fixtures/Equipment: Provide Class 5 Vault door in compliance with
[AEI]. [Insert any requirements for arms rack anchor rings, comm storage racks, etc].
Floor: sealed concrete
Base: none.
Walls: painted concrete
Ceiling: painted concrete. Minimum ceiling height shall be [2800 mm] [verify ceiling height with
user].
2-2.2.16.5 Other requirements: Provide HVAC system to control relative humidity to [__]% plus
or minus [__]% [coordinate environmental requirements with user].
2-2.2.17 COMSEC Vault. [Include this paragraph if the organization is authorized a
maintenance building larger than 1,000 m2.]Provide one. Locate on first floor; minimum net area
shall be 28 m2. Minimum dimensions shall be 4000 mm x 7000 mm. Total occupants: [__] [one
COMSEC Vault is authorized per organization requiring greater than 1,000 m2 of maintenance
building.]. Provide GSA approved Class 5 vault door [with day gate] between COMSEC Vault
and core Corridor. Walls, floor and ceiling of Vault shall be concrete masonry or concrete; and
all openings and penetrations shall be constructed in compliance with [Army Technical
Instruction TI 800-01 and AR 190-11.] [insert applicable requirements].
2-2.2.17.1 Function: Secure storage of communications equipment, crypto gear.
2-2.2.17.2 Adjacency requirements: Adjacent to Corridor.
2-2.2.17.3 Furnishings/Fixtures/Equipment: Provide Class 5 Vault door in compliance with
[AEI]. [Insert any requirements for comm racks or storage shelving].
Floor: sealed concrete
Base: none.
Walls: painted concrete
SOW-27