UFC 4-214-02, 24 Jul 03
Base: [none] [resilient, if gypsum board partitions used]
Walls: painted concrete masonry units. Exposed structure shall be painted.
Ceiling: suspended acoustical panel ceiling; minimum ceiling height 2800 mm .
2-2.2.7.5 Other requirements: Provide [___] wall mounted compressed air outlets. [Exterior
windows are desirable.] [Provide operable exterior windows for testing sights] [Coordinate with
user] [ ].
2-2.2.8
Special Environment Repair. Provide one [or more] area[s] per core. Locate on
first floor [or second floor]; minimum total net area shall be [____] m2 . Total occupants: [__]
[When this area is authorized for an activity, space is authorized at 13.95 m2 net area per each
person assigned to the room (includes 9.3 m2 plus 4.65 m2 for circulation)]. Provide pair of
personnel doors between Special Environment Repair and core Corridor. Provide [pair of
personnel doors] [overhead coiling door (1800 mm wide x 2200 mm high) and swinging
personnel door] to exterior, for pedestrian circulation and movement of items.] [Verify exterior
access requirements with user]. Walls or partitions between this space and the Circulation
Bay, and Corridor [, and shop spaces] shall be concrete masonry or concrete; [other partitions
may be metal studs with abuse-resistant gypsum wallboard] [although durability is reduced,
initial cost is lower, and future flexibility is increased by allowing use of metal stud/drywall
partitions; edit as necessary]
2-2.2.8.1 Function: Shop space with supplemental air filtering requirements, for repair of
[audio visual equipment, anti-aircraft missiles, MLRs, radios, telecommunications terminal
devices, communications central switch equipment, communications security (encryption)
equipment, tactical and strategic electronic warfare and intelligence equipment, land combat
support system test equipment for anti-tank missiles, surveillance radar, wire communications
systems, automated test equipment, small arms, artillery, fire control, weather prediction
Measurement, and Diagnostic Equipment (TMDE).] [Edit this paragraph as required].
2-2.2.8.2 Adjacency requirements: Adjacent to Corridor; [adjacent to exterior wall] [Include if
area requires exterior windows or doors]. [Near other shop areas].
2-2.2.8.3 Furnishings/Fixtures/Equipment: Design the space to accommodate the following
government provided furniture and equipment [list everything the user will have in the space;
include sizes.]. [Provide, and design space to accommodate the following: _____] [Coordinate
with user. If not provided by the activity, list required workbenches, storage shelving, racks,
cabinets, etc]. Provide emergency eyewash. [Provide workbench exhaust system at ___ bench
locations capable of removing exhaust from the following operations:_______; exhaust systems
shall comply with OSHA, and applicable NFPA and building codes] [Include a list of all
functions, processes, and gasses generated, etc. at the locations that require exhaust systems.
Add additional military compliance requirements if they exceed code requirements.]
Floor: epoxy coating on concrete slab
Base: [none] [resilient, if gypsum board partitions used]
Walls: painted concrete masonry units. Exposed structure shall be painted.
Ceiling: suspended acoustical panel ceiling; minimum ceiling height 2800 mm .
2-2.2.8.5 Other requirements: Provide [___] wall mounted compressed air outlets. [Exterior
windows are desirable.] [Provide operable exterior windows for testing sights] [Coordinate with