Project Name
Project Number
TEMF
Statement of Work
UFC 4-214-02, 24 Jul 03
2-2.2.3.5 Other requirements: [
].
2-2.2.4
PLL Storage. Provide one PLL Storage Room for each wing of Repair Bays (if
Repair Bays are located on both sides of a core, each side of core shall have a PLL Storage
Room). Locate on first floor; minimum total net area of all PLL Storage Rooms shall be [____]
m2 . Total occupants: [__] [Space is authorized at .19 m2 net area per each occupant of the
facility]. Provide personnel door between PLL Storage and core Corridor. Provide [ __mm high
x __mm wide] pass-through opening with stainless steel counter and metal overhead coiling
shutter between PLL Storage and Circulation Bay. Walls or partitions between this space and
the Circulation Bay, and Corridor [, and shop spaces] shall be concrete masonry or concrete;
[other partitions may be metal studs with abuse-resistant gypsum wallboard] [although
durability is reduced, initial cost is lower, and future flexibility is increased by allowing use of
metal stud/drywall partitions; edit as necessary]. Partition between this space and RX/TS shall
be wire mesh.
2-2.2.4.1 Function: Storage and issue of Prescribed Load List (PLL) items (parts kept in stock
at all times because of demand or management decisions).
2-2.2.4.2 Adjacency requirements: Adjacent to Circulation Bay, Corridor, and RX/TS.
2-2.2.4.3 Furnishings/Fixtures/Equipment: Design the space to accommodate the following
government provided furniture and equipment [list everything the user will have in the space;
include sizes.]. [Provide, and design space to accommodate the following storage systems:
_____] [Coordinate with user. If not provided by the activity, list required storage shelving,
racks, cabinets, etc].
Floor: epoxy coating on concrete slab
Base: [none] [resilient, if gypsum board partitions used]
Walls: painted concrete masonry units. Exposed structure shall be painted.
Ceiling: exposed structure, painted.
2-2.2.4.5 Other requirements: [
].
2-2.2.5
RX/TS (Repairable Exchange/Technical Supply). [Delete paragraph if RX/TS
space is not authorized] Provide one RX/TS Room for each wing of Repair Bays (if Repair Bays
are located on both sides of a core, each side of core shall have a RX/TS Room). Locate on
first floor; minimum total net area of all RX/TS Rooms shall be [____] m2 . Total occupants:
[__]. [When this area is authorized for organizational shops, space is authorized at 27.9 m2 net
area per the first Equipment Records and Parts Specialist, and 11.9 m2 per each additional
person assigned to this space]. Provide pair of personnel doors between RX/TS and core
Corridor. Walls or partitions between this space and the Circulation Bay, and Corridor [, and
shop spaces] shall be concrete masonry or concrete; [other partitions may be metal studs with
abuse-resistant gypsum wallboard] [although durability is reduced, initial cost is lower, and
future flexibility is increased by allowing use of metal stud/drywall partitions; edit as necessary].
Partition between this space and PLL Storage shall be wire mesh.
2-2.2.5.1 Function: Temporary storage of repairable items that will be exchanged for new
items. This room is also used to store parts ordered on an as-needed basis from the supporting
direct support activity.
SOW-19