Project Name
Project Number
TEMF
Statement of Work
UFC 4-214-02, 24 Jul 03
the space to accommodate government provided] [Provide] parts washer, solvent
disposal/recycle system [include size, capacity, make and model of systems; quantities,
Floor: epoxy coating on concrete slab
Base: [none] [resilient, if gypsum board partitions used]
Walls: painted concrete masonry units. Exposed structure shall be painted.
Ceiling: suspended acoustical panel ceiling; minimum ceiling height 2800 mm .
2-2.2.6.5 Other requirements: Provide [___] wall mounted compressed air outlets. [Provide
operable exterior windows] [Exterior windows are desirable].
2-2.2.7
Compact Item Repair. Provide one [or more] area[s] per core. Locate on first floor
or second floor; minimum total net area shall be [____] m2 . Total occupants: [__] [When this
area is authorized for an activity, space is authorized at 9.6 m2 net area per each person
assigned to the room (includes 6.4 m2 plus 3.2 m2 for circulation)]. Provide pair of personnel
doors between Compact Item Repair and core Corridor. If located adjacent to General Item
Repair, [the partition between this space and General Item Repair shall be wire mesh] [the
spaces do not require a partition between them] [Verify with user, delete wire mesh partition if
possible]. Walls or partitions between this space and the Circulation Bay and Corridor [, and
shop spaces] shall be concrete masonry or concrete; [other partitions may be metal studs with
abuse-resistant gypsum wallboard] [although durability is reduced, initial cost is lower, and
future flexibility is increased by allowing use of metal stud/drywall partitions; edit as necessary]
2-2.2.7.1 Function: Shop space for maintenance of radios, telephones, small switchboards,
and personal computers. Repair of medically related optical, mechanical, electrical, plumbing,
pneumatic, refrigeration, and low capacity x-ray equipment. [In DPW facilities] [This area also
includes space for repair of audio-visual equipment, diagnostic equipment and instruments
(such as thermostats, meters, monitoring equipment)] [edit this paragraph as required].
2-2.2.7.2 Adjacency requirements: Adjacent to Corridor; [adjacent to exterior wall] [Include if
area requires exterior windows]. [Adjacent to General Item Repair] [If the Compact Item Repair
area is small, it may be advantageous to locate adjacent to General Item Repair. In facilities
with large Compact Item Repair areas, it may be better to allow the designer the flexibility to
locate Compact Item Repair on the second floor, or to split the Compact Item Repair area into
first and second floor rooms; verify acceptability of this arrangement with user.]
2-2.2.7.3 Furnishings/Fixtures/Equipment: Design the space to accommodate the following
government provided furniture and equipment [list everything the user will have in the space;
include sizes.]. [Provide, and design space to accommodate the following: _____] [Coordinate
with user. If not provided by the activity, list required workbenches, storage shelving, racks,
cabinets, etc]. Provide emergency eyewash. . [Provide workbench exhaust system at ___
bench locations capable of removing exhaust from the following operations:_______; exhaust
systems shall comply with OSHA, and applicable NFPA and building codes] [Include a list of all
functions, processes, and gasses generated, etc. at the locations that require exhaust systems.
Add additional military compliance requirements if they exceed code requirements.]
Floor: epoxy coating on concrete slab
SOW-21