Project Name
Project Number
TEMF
Statement of Work
UFC 4-214-02, 24 Jul 03
2-2.2.19.1 Function: Lockers and showers for male occupants.
2-2.2.19.2 Adjacency requirements: Adjacent to corridor, adjacent to Men's Locker Room.
Accessible from Men's Toilet Room without going through Corridor.
2-2.2.19.3 Furnishings/Fixtures/Equipment: Provide the following toilet accessories: one 406
mm wide x 1524 mm high wall mounted mirror; one liquid soap dispenser per shower. [Provide
one solid polymer plastic dressing partition with door and hardwood bench, in front of each
shower compartment]. Toilet accessories shall be fabricated from stainless steel, provide semi-
recessed units where possible. Provide hardwood locker room benches. Provide minimum of
one floor drain with deep seal trap at each drying area.
Floor: porcelain tile, or ceramic tile.
Base: porcelain tile, or ceramic tile.
Walls: ceramic tile.
Ceiling: painted Portland cement plaster, or painted gypsum soffit board; minimum ceiling height
2800 mm.
2-2.2.19.5 Other requirements: Provide handicapped accessibility in conformance with
ADA/UFAS. Provide at least one accessible shower/dressing area. Provide at least [2]
accessible lockers.
2-2.2.20 Women's Toilet Room. Provide one room on each floor of each core, sized to
accommodate the number of plumbing fixtures required. Number of fixtures shall be as required
by International Plumbing Code (Business occupancy). Calculate fixture requirement on the
following male-to-female occupant ratios: Repair Bays: _-to-1; Warehouse Bay spaces: _-to-1;
Admin and Shop Control: _-to-1; other core spaces: _-to-1. Toilet Room and Locker Room
should share common entrance off of Corridor. Arrange entrance to provide visual privacy.
Walls or partitions between this room and other spaces [shall be concrete masonry or concrete]
[may be metal studs with water-resistant gypsum wallboard; where ceramic tile finish is
indicated provide glass mesh mortar units (cementitious tile backer board) in lieu of gypsum
wallboard].
2-2.2.20.1 Function: Restrooms for female occupants.
2-2.2.20.2 Adjacency requirements: Adjacent to corridor, first floor Women's Toilet Room
adjacent to Women's Locker Room.
2-2.2.20.3 Furnishings/Fixtures/Equipment: Provide countertop mounted lavatories, and floor
mounted toilets. Countertops shall be plastic laminate or solid surfacing material. Provide toilet
partitions at each toilet. Partitions shall be solid polymer plastic, overhead-braced type. Provide
the following toilet accessories: one continuous mirror full width of countertop at countertop
mounted lavatories; one paper towel dispenser/waste receptacle per toilet room; one soap
dispenser per lavatory; one toilet tissue dispenser per toilet; one sanitary napkin disposal per
toilet; one robe hook on each toilet partition door; one sanitary napkin/tampon vending machine.
Toilet accessories shall be fabricated from stainless steel, provide semi-recessed units where
possible. Provide minimum of one floor drain with deep seal trap; locate floor drain outside of
traffic areas.
SOW-29