UFC 4-171-05
1 January 2005
with change 25 October 2006
4-2.25
Controlled Waste Storage
These rooms are rarely provided in training centers; see OMS Controlled Waste
Storage, Section 4-3.8 below.
4-2.26
Facility Maintenance Storage
4-2.26.1 This space is provided for storage of maintenance equipment and supplies,
and general building storage. The authorization may be distributed throughout larger
buildings for operational convenience.
4-2.26.2 A portion of this space should be dedicated to recycling, for sustainable
design and environmental reasons. This portion should be located near an exterior exit
with vehicle access, and a recycling sorting station should be provided.
4-2.26.3 Space Design Information
General/Code
Size 200 sf (18.6 sq m)
Occupancy business
Occupancy count not occupied; typically 1 person per 300 sf
Architectural/Interiors
Figure 4-24
Minimum STC rating 40
Facility Maintenance Storage
Ceiling height
Floor sealed concrete
Base none
Walls painted gypsum board;
painted CMU as an alternative
Ceiling exposed structure, painted
Trim none
Lockset storeroom
Mechanical
Coolng - none
fan
electrical
Lighting 30 fc
Voice/data wall phone
Furniture
equipment
Shelving and or storage cabinets
special features or considerations
Ordinary hazard sprinklers
112