Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Base: ceramic tile sanitary cove base
Walls: painted water-resistant gypsum wallboard or painted veneer plaster, or ceramic tile, or
ceramic tile wainscot. Walls around shower/tub enclosure shall be full height ceramic tile, or
material with equivalent scratch-resistance, water-resistance, and durability.
Ceiling: painted exterior gypsum soffit board, or painted veneer plaster, painted Portland cement
plaster, or painted underside of precast concrete structural floor planks.
2-2.1.4.5 Other requirements: HVAC system shall exhaust bathroom air; refer to Chapter 10.
Door shall have privacy function (F76) lockset.
2-2.1.5
Module Mechanical Area. Mechanical units may be located above ceilings, or in
separate mechanical closets; or through-wall packaged units may be used. Refer to Chapter
10. If mechanical closet is provided, the following requirements will apply:
2-2.1.5.1 Function: Houses HVAC unit for the module. Room shall not be used for storage or
any purpose not related to the mechanical system. Access will be limited to maintenance
personnel.
2-2.1.5.2 Adjacency requirements: Adjacent to and accessible only from exterior or public
corridor or breezeway.
2-2.1.5.3 Furnishings/Fixtures/Equipment: Provide mechanical system. Refer to Chapter 10.
Floor: sealed concrete
Base: none required
Walls: painted gypsum wallboard, painted veneer plaster, or painted concrete masonry units.
Ceiling: : painted gypsum wallboard, or painted veneer plaster, or painted underside of precast
concrete structural floor planks
2-2.1.5.5 Other requirements: Provide swinging door sized to allow maintenance and removal
of mechanical unit(s). Door shall have storeroom function (F86) lockset. Room construction
shall comply with fire and smoke separation requirements of applicable codes.
2-2.2
Areas Comprising the One-Person Living Unit (Module). Each One-Person living
unit, or module, will contain a living/sleeping room with closet, a service area with kitchenette,
and a bathroom. Spaces are as follows.
2-2.2.1
Living/Sleeping Room. Minimum net area 13 m2 [140 sf]. Maximum net area 17
m2 [182 sf]. Provide one per module.
2-2.2.1.1 Function: Private bedroom and living space for one senior enlisted person.
2-2.2.1.2 Adjacency requirements: Adjacent to service area and closet. Living/sleeping room
shall be entered from service area, or the public interior corridor or breezeway. 750mm [2'-6"]
wide door between service area and living/sleeping room may be provided, or room may be
arranged like an efficiency apartment without door between kitchenette and living/sleeping area.
If living/sleeping room is entered directly from interior corridor or breezeway, provide 900mm
[3'-0"] wide entry door swinging into room.
2-2.2.1.3
Furnishings/Fixtures/Equipment: Provide, and design the room to accommodate,