Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-2.2.3.2 Adjacency requirements: Adjacent to Living/sleeping room and bathroom. If Service
Area is entered from public corridor or breezeway, provide 900mm [3'-0"] wide entry door
swinging into room
2-2.2.3.3 Furnishings/Fixtures/Equipment: Provide refrigerator-freezer (minimum 9 total cubic
feet). Provide microwave oven (min .9 cubic feet, 800 watts) mounted under wall cabinets.
Provide minimum 2-burner electric cooktop, or 2-burner electric range with self-cleaning oven.
Provide range hood with exterior exhaust. Provide minimum 1500 linear mm [5'-0"] of 600mm
[2'-0"] deep kitchen base cabinets and countertop (including cooktop/range width), and 2100
linear mm [7'-0"] of 300mm [12"] deep wall cabinets. Wall cabinets shall be minimum 600mm
[2'-0"] high; provide 600 mm [2'-0"] clear between countertop and bottom of wall cabinets at
sink. Base cabinets shall have minimum of two 300 mm [12"] wide drawers. Provide plastic
laminate countertop with side and backsplashes at walls. Provide single compartment,
stainless steel kitchen sink with food strainer/stopper, minimum inside dimensions 400mm x
400mm x 175mm deep [1'-4" x 1'-4" x 7" deep], with chrome-plated, single handle, washerless
mixing faucet (refer to Chapter 8). Provide, and design room to accommodate, the following
furnishings: one dining table for two persons, 750mm square x 725mm high [30" x 28-1/2" high]
with two armless dining chairs. Provide fire extinguisher mounted inside base cabinet.
[Providing residential type clothes washer and dryer in each living unit is a HQ approved option.
If the design district is considering use for this project, coordination with user and installation
facilities engineer (DPW) is essential. Carefully weigh the benefits and drawbacks of providing
laundry appliances in each unit. Appliances shall be Energy Star compliant. Note, also, that for
optimum performance and minimum maintenance and fire hazard, dryers should exhaust to the
exterior with as little ductwork as possible; this puts additional design parameters on the
arrangement of the floor plan of the units].
Base: resilient cove base
Walls: painted gypsum wallboard or painted veneer plaster
Wall area between countertop and wall cabinets: ceramic tile, plastic laminate, or color coordinated
back wall shield (if unitized kitchen is used)
Ceiling: painted gypsum wallboard, painted veneer plaster, or painted underside of precast
concrete structural floor planks
2-2.2.3.5 Other requirements: At wall areas around dining table provide chair rail or similar
wall protection to protect walls from chair and table impact. It is desirable, but not required, to
have exterior window in room. Window shall not be located adjacent to an exterior corridor or
breezeway. Door between public corridor and service area (entry door into module) shall have
mortise dormitory function (F13) lockset.
2-2.2.4
Bathroom. Provide one per module.
2-2.2.4.1
Function: Bathing and toilet facilities for occupant; storage for occupants' bath
articles.
2-2.2.4.2 Adjacency requirements: Adjacent to service area or interior hallway. Provide
610mm [2'-0"] wide door between bathroom and service area or hallway.
2-2.2.4.3 Furnishings/Fixtures/Equipment (FFE): Lavatory shall be minimum 483mm x 483mm
[19" x 19"] self-rimming vitreous china, or cast-filled acrylic or solid surfacing material integrally
SOW-10