Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
operation of ice dispenser if desired]. Provide ice machine manufacturer's automatic cleaning
system to clean and sanitize the water distribution system of the machine at scheduled
intervals. Ice machine shall be Energy Star compliant. Design the space to accommodate four
full-size soft drink and snack vending machines (government furnished, government installed).
Vending machines will not require plumbing connections.
2-2.3.7.4 Finishes: Match entry lobby or adjacent corridor or breezeway.
2-2.3.7.5 Other requirements: First floor vending areas shall be handicap accessible. Provide
floor drain near ice machines; locate drain outside of traffic area. If door is provided, door shall
have classroom function (F84) lockset.
2-2.3.8
Public Telephone Area. Provide one. [If climate allows, consider the possibility of
locating additional pay telephones in outdoor kiosks or phone booths. Require coordination of
kiosk design with UEPH building design and the Installation Design Guide. Include applicable
requirements of the IDG in this Statement of Work.]
2-2.3.8.1 Function: Pay telephones for barracks occupants and visitors.
2-2.3.8.2 Adjacency requirements: Near lobby and CQ station.
2-2.3.8.3 Furnishings/Fixtures/Equipment: Provide three pay telephones and telephone
stations. Offeror shall contract with local telephone company or other telephone service
provider to furnish and install pay telephones; rate charged for calls shall not exceed the
average prevailing rate in the local off-post community. Each station will have divider panels to
enhance acoustical privacy. Provide built-in seating at two stations; third station shall be
wheelchair accessible. Provide capability to mount portable TDD at one station. Materials shall
be vandal resistant and easily cleaned.
2-2.3.8.5 Other requirements: Handicap accessible.
2-2.3.9
Mail Room. Provide one. Room shall be sized to allow access to all rear-loading
mailboxes and parcel lockers. Provide minimum 1829 mm [6'-0"] clear between back of
mailboxes and any obstructions. To comply with force protection minimum standards, avoid
routing key utilities (including communications, fire detection and alarm, water mains, etc.)
through or on common walls to mail room.
2-2.3.9.1 Function: Secure area for sorting incoming mail and distributing to rear-loading
mailboxes.
2-2.3.9.2 Adjacency requirements: Near CQ station and entry lobby. To comply with force
protection minimum standards, locate mailroom on perimeter of building.
2-2.3.9.3 Furnishings/Fixtures/Equipment: Provide plastic laminate-faced sorting counter
(built-in casework) 762 mm [2'-6"] deep x minimum 2438 mm [8'-0"] long x 914 mm [3'-0"] high.
Provide United States Postal Service approved mailbox for each resident of the facility. Provide
minimum of nine parcel lockers, and one outgoing mail collection box.
2-2.3.9.4 Finishes:
SOW-15