Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-2.3.5.2 Adjacency requirements: Adjacent to entry lobby and CQ station.
2-2.3.5.3 Furnishings/Fixtures/Equipment: Floor mounted toilet; wall hung lavatory; recessed
multifold paper towel dispenser/trash receptacle; two roll toilet tissue dispenser; sanitary napkin
disposal; liquid soap dispenser; wall mounted mirror over lavatory; wall mounted grab bars at
toilet.
Floor: Ceramic tile, or porcelain tile
Base: Ceramic tile, or porcelain tile
Walls: Ceramic tile, ceramic tile wainscot, or painted water-resistant gypsum wallboard
Ceiling: painted gypsum wallboard, painted veneer plaster, painted portland cement plaster, or
painted underside of precast concrete structural floor planks.
2-2.3.5.5 Other requirements: Handicap accessible. Entry door shall have privacy function
(F76) lockset.
Janitor Closet. Provide one on each floor of building. Minimum area 2.8 m2 [30 sf]
2-2.3.6
each.
2-2.3.6.1 Function: Sink, and storage of cleaning supplies.
2-2.3.6.2 Adjacency requirements: Near toilet room on first floor; preferred location on upper
floors is adjacent to laundry areas.
2-2.3.6.3 Furnishings/Fixtures/Equipment: Provide floor mop sink, mop rack for three mops,
and minimum 1829 linear mm of wall mounted stainless steel shelving.
Floor: ceramic tile, or sealed concrete
Base: resilient cove base, or ceramic tile base
Walls: painted water-resistant gypsum wallboard, or painted concrete masonry units
Ceiling: painted gypsum wallboard, painted veneer plaster, or painted underside of precast
concrete structural floor planks.
2-2.2.6.5 Other requirements: door shall have classroom function (f84) lockset.
2-2.3.7
Vending Area. Provide minimum one area on ground floor. Additional vending
areas with ice machine-dispensers may be provided at upper floors as a proposed betterment
over the minimum requirement. [If climate allows, consider the possibility of allowing vending
machines and ice machine-dispensers to be located in securable outdoor areas. Ice dispensers
may require card key type access control or coin operation if located in an unsupervised area.]
2-2.3.7.1 Function: Space for soft drink and snack vending machines, and ice machine-
dispenser.
2-2.3.7.2 Adjacency requirements: Near entry lobby.
2-2.3.7.3 Furnishings/Fixtures/Equipment: Provide one ice cube machine-dispenser designed
for hotel ice bucket filling, capable of producing minimum 250 lbs. of regular ice cubes in 24
hours, with 180 lb. storage capacity [Add requirement for room card type access or coin
SOW-14