Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Base: resilient cove base
Walls: painted gypsum wallboard or painted veneer plaster, or painted concrete masonry units
Ceiling: painted gypsum wallboard, painted veneer plaster, or painted underside of precast concrete
structural floor planks.
2-2.3.9.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
mortise dormitory function (F13) lockset. Room shall be handicap accessible. Design shall
comply with United States Postal Service regulations.
2-2.3.10 Mailbox Access Area. Provide an area from which residents may access
mailboxes to pick up their mail. Access may be from a covered exterior area or from an interior
lobby. Mailboxes will be loaded from the interior mail room.
2-2.3.10.1 Function: Mail pickup area for residents.
2-2.3.10.2 Adjacency requirements: Adjacent to mail room. Located on ground floor, near CQ
station and entry lobby.
2-2.3.10.3 Furnishings/Fixtures/Equipment:
2-2.3.10.4 Finishes: Interior: match entry lobby. Exterior: refer to exterior building material
requirements.
2-2.3.10.5 Other requirements: For exterior location provide minimum 1829 mm [6'-0"] of
covered area in front of mailboxes (recess, building overhang, etc.) for weather protection; it is
preferable to provide continuous covered area between mailbox access area and main entry.
Provide adequate drainage at exterior areas.
2-2.3.11 Laundry Area(s).
||content||
\ [Delete if washer and dryer is provided in each living unit.
Garrison Commander has discretion to locate in each module, each floor, or each barracks.] /1/
Provide one clothes washer per 12 residents, and 1.5 clothes dryers per washer (round
fractional numbers to the next highest whole number). Provide minimum of one laundry room
on each floor of the UEPH facility. Additional laundry rooms are acceptable; provide minimum
four washers and six dryers in each room.
2-2.3.11.1 Function: Self-service washers and dryers and clothes folding areas for residents.
2-2.3.11.2 Adjacency requirements: Locate laundry rooms on exterior walls so dryers can be
exhausted directly to exterior. Locate dryer exhaust wall caps away from operable windows.
For noise considerations, it is preferable not to locate laundry rooms adjacent to living units
(shared walls).
2-2.3.11.3 Furnishings/Fixtures/Equipment: Commercial quality clothes washers and dryers
(each minimum 2.5 cubic feet capacity), non-coin operation. Stacked dryers are preferred.
Appliances shall be Energy Star compliant. Provide one plastic laminate-faced table with
clothes hanging rod (minimum table size:1219 mm x 610 mm x 914 mm high [48" x 24" x 36"
high]) per each four washers. Provide two vandal-resistant waiting chairs per each four
washers. Provide space for one wall mounted laundry product vending machine in each laundry
room (not in contract).