2-2.4.2.2 Adjacency requirements: Adjacent to vertical circulation.
2-2.4.2.3 Furnishings/Fixtures/Equipment (FFE): Provide mechanical and electrical systems to
comply with applicable codes. Provide fire extinguishers in semi-recessed fire extinguisher
cabinets to comply with applicable codes. All fixtures and equipment shall be suitable for
exterior locations.
Floor: sealed concrete
Base: Exterior wall material
Walls: Exterior wall material
Ceiling: painted exterior gypsum soffit board, painted Portland cement plaster, or painted
underside of precast concrete structural floor planks.
2-2.4.2.5 Other requirements: Handicap accessible. With the exception of fire sprinkler
systems, no piping, conduit or ductwork shall be exposed in breezeway. Provide slip resistant
finish texture on concrete floor.
2-2.4.3
Exterior Corridor. Refers to an unconditioned, covered circulation space that is
enclosed on one long side (adjacent to the building), and has a guardrail on the other side.
Provide as required to allow circulation to building spaces and comply with applicable code
egress requirements. When breezeways are used to provide access to living units, exterior
corridors may be provided to link breezeways with stairs and other circulation components.
Exterior corridors shall not be used to provide access to living units [HQ guidance disallows
entering a living unit from an exterior corridor (although breezeways are acceptable). Edit as
necessary to retain or delete use of exterior corridors. Exterior corridors are not recommended
for very cold climates, nor where security and force protection are controlling issues. Metal
guardrails can create an additional maintenance concern.]
2-2.4.3.1
Function: Circulation and means of egress.
2-2.4.3.2 Adjacency requirements: Adjacent to vertical circulation.
2-2.4.3.3 Furnishings/Fixtures/Equipment (FFE): Provide mechanical and electrical systems to
comply with applicable codes. Provide fire extinguishers in semi-recessed fire extinguisher
cabinets to comply with applicable codes. All fixtures and equipment shall be suitable for
exterior locations.
Floor: sealed concrete
Base: Exterior wall material
Walls: Exterior wall material
Ceiling: painted exterior gypsum soffit board, painted Portland cement plaster, or painted
underside of concrete structure above
2-2.4.3.5 Other requirements: Handicap accessible. With the exception of fire sprinkler
systems, no piping, conduit or ductwork shall be exposed in exterior corridor. Provide slip
resistant finish texture on concrete floor. Guardrails shall be painted hot dip galvanized steel, or
prefinished aluminum rail system designed in accordance with applicable codes.