Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
reconfigured for four small companies). COF functions and areas shall be as follows:
2-3.1
COF Administrative Areas. Provide one group of administrative areas per
company. Company leadership will manage the organization, receive visitors, and conduct day-
to-day business from the COF administrative areas. Provide an easily identified, covered
entrance. Entrance shall be separate and distinct from the entrances to company supply areas
and to other COF administrative areas. Exterior wall space above or adjacent to the entrance
will be used to display company identification signage. Provide interior circulation to company
supply areas. Military personnel will staff the facility; military and non-military personnel will
visit the administrative areas to meet with leadership or attend meetings in the conference room.
Although only able-bodied military personnel will be on staff, all administrative spaces except
private shower rooms shall comply with UFAS and ADA requirements (this requirement applies
whether administrative spaces are located on first or second floor). Provide the following areas
for each company:
Company Commander (CO). Provide one; 13.9 m2 [150 sf]. Room shall be
2-3.1.1
accessed through the Admin Office. Occupants: 1, and occasional visitors.
2-3.1.1.1 Function: Private office for commanding officer.
2-3.1.1.2 Adjacency requirements: Adjacent to Admin Office; near XO, 1st SGT, and Training
Office.
2-3.1.1.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
conference table [___], four side chairs, and one desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-3.1.1.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Room shall have exterior window. Partitions shall have minimum
STC rating of 55.
Executive Officer (XO). Provide one; 9.3 m2 [100 sf]. Room shall be accessed
2-3.1.2
through the Admin Office. Occupants: 1, and occasional visitors.
2-3.1.2.1 Function: Private office for the company executive officer.
2-3.1.2.2 Adjacency requirements: Adjacent to Admin Office; near CO, 1 SGT, and Training
Office.
2-3.1.2.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair and one desk chair. Provide a floor anchor for one GFGI security safe, approximate
dimensions [______], weight [___]. Coordinate anchor location with furniture layout; refer to
paragraph 5-6.4.
SOW-23