Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-3.1.4.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Exterior window is desirable. Partitions shall have minimum STC
rating of 55.
Admin Office. Provide one area; minimum 35.3 m2 [380 sf], including interior
2-3.1.5
circulation. Room shall be accessed through the Waiting Area. Occupants: 2 clerks, and
occasional visitors.
2-3.1.5.1 Function: Office for company administrative clerks, storage of files, access to private
offices. Clerks will have visual control of waiting area and conference room door.
2-3.1.5.2 Adjacency requirements: Adjacent to Waiting Area; CO, XO, 1 SGT, and Training
Office. Adjacent to or near Conference Room. Near main entrance to Administrative Area.
2-3.1.5.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate [_] clerk
desks [____] with returns [____] and desk chairs, [insert info on other required furnishings].
Provide reception desk (built-in casework) minimum 1829 mm [6'-0"] long separating the Admin
Office from the Waiting Area. The counter on the Waiting Area side shall be 1016 mm high x
305 mm deep [If user desires a method of securing Admin Office from Waiting Area, add
requirement for overhead coiling grille or sliding pass-through window above counter]. Admin
side of reception desk shall be at desk height, and shall accommodate computer and monitor
(not in contract), and writing area. Provide built-in communication and power receptacles or
grommets in desk top to access wall receptacles. Desk shall have knee space and minimum
two cabinets with hinged doors, and two drawers. Drawers and cabinets shall have keyed
locks. Desk components shall have plastic laminate or stained wood finish. Provide a floor
anchor for one GFGI security safe, approximate dimensions [_____], weight [___]. Coordinate
anchor location with furniture layout; refer to paragraph 5-6.4.
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-3.1.5.5 Other requirements: Provide 914 mm [3'-0"] wide entry door into room from Waiting
Area; door shall have entry function (F81) lockset. Exterior window is desirable.
Admin Storage. Provide one; minimum area 3.3 m2 [35 sf]. Room shall be
2-3.1.6
accessed from the Admin Office.
2-3.1.6.1 Function: Closet for storage of supplies, paper, etc.
2-3.1.6.2 Adjacency requirements: Adjacent to Admin Office.
2-3.1.6.3 Furnishings/Fixtures/Equipment:
SOW-25