Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Ceiling: painted Portland cement plaster, or painted gypsum wallboard or veneer plaster.
2-4.10.4.5 Other requirements:
2-4.10.5 Shower Room. Provide two. Rooms shall be used by able-bodied military personnel
only. Rooms shall be accessed from Administrative Area Corridor. Shower room shall not be
combined with toilet rooms. In a two-story building, shower rooms may be located on first or
second floor.
2-4.10.5.1 Function: Private shower and dressing room for use by battalion staff.
2-4.10.5.2 Adjacency requirements: Adjacent to corridor. Near toilets.
2-4.10.5.3 Furnishings/Fixtures/Equipment: Provide one ceramic tile shower with rod and
shower curtain. Shower shall have ceramic soap holder and wall mounted grab bar. Dressing
area shall have bench, four towel/robe hooks, and wall mounted full-length mirror. Provide floor
drain at dressing area, locate outside of circulation path.
Floor: ceramic tile.
Base: ceramic tile.
Walls: ceramic tile
Ceiling: painted Portland cement plaster.
2-4.10..6.5 Other requirements:
2-4.10.6 Janitor Closet. Provide one at each group of toilets on each floor of the building.
Minimum area: 2.8 m2 [30 sf]. Room shall be accessed from the corridor.
2-4.10.6.1 Function: Sink and storage of cleaning supplies, soap, paper products.
2-4.10.6.2 Adjacency requirements: Near toilets and shower rooms.
2-4.10.6.3 Furnishings/Fixtures/Equipment: Provide one floor mounted mop sink, mop rack for
two mops, and minimum 1829 linear mm of wall mounted stainless steel shelving.
Floor: ceramic tile, or sealed concrete
Base: resilient cove base, or ceramic tile base
Walls: painted water-resistant gypsum wallboard, or painted concrete masonry units
Ceiling: painted gypsum wallboard, painted veneer plaster, or painted Portland cement plaster
2-4.10.6.5 Other requirements: Door shall have classroom function (F84) lockset.
2-4.10.7 Storage. Provide minimum 9.3 m2 [100sf] of general storage space. In a two-story
building provide half of the area on each floor. Each room shall be dedicated to one battalion.
Storage rooms will be accessed from the corridor.
2-4.10.7.1 Function: Storage of [identify type of items to be stored] for the battalion.
2-4.10.7.2 Adjacency requirements: Adjacent to corridor.
SOW-57