Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-5.1.1.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] one credenza [____], one bookcase [___], two legal-size four-drawer file cabinets,
one conference table [___], six side chairs, and one desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.1.1.5 Other requirements: Provide 914 mm [3'-0"] wide doors into room from reception
area and from Conference Room; doors shall have entry function (F81) lockset (CO office is
secure side). Room shall have exterior window. Partitions shall have minimum STC rating of
55.
Executive Officer (XO). Provide one; 13.9 m2 [150 sf]. Room shall be accessed
2-5.1.2
through the Reception Area. Occupants: 1, and occasional visitors.
2-5.1.2.1 Function: Private office for brigade executive officer.
2-5.1.2.2 Adjacency requirements: Adjacent to Reception Area, S-1/PAC Clerical /Central
Files. Adjacent to or near command section toilet, coffee area, CO office and Command
Sergeant Major office. [modify this sentence if direct access door from CO to XO is required].
2-5.1.2.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets,
three side chairs, and one desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-4.1.2.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Room shall have exterior window. Partitions shall have minimum
STC rating of 55.
Command Sergeant Major (CSM). Provide one; 13.9 m2 [150 sf]. Room shall be
2-5.1.3
accessed through the Reception Area. Occupants: 1, and occasional visitors.
2-5.1.3.1 Function: Private office for brigade command sergeant major.
2-5.1.3.2 Adjacency requirements: Adjacent to Reception Area, S-1 Clerical /Central Files.
Adjacent to or near command section toilet, coffee area, CO office and Command Sergeant
Major office. [modify this sentence if direct access door from CO to XO is required].
2-5.1.3.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets,
three side chairs, and one desk chair.
SOW-61