Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
so that door does not open directly into reception area. Partitions shall have minimum STC
rating of 49.
2-5.1.6
Coffee Area. Provide one. Area shall have countertop with kitchen sink; comply with
handicap accessibility requirements.
2-5.1.6.1 Function: Sink and space for coffee maker and supplies; for use by command
section staff and visitors.
2-5.1.6.2 Adjacency requirements: Adjacent to Reception Area. Near CO, XO, and CSM
offices. Locate to avoid conflicts with circulation pattern.
2-5.1.6.3 Furnishings/Fixtures/Equipment (FFE): Provide minimum 1219 mm wide x 610 mm
deep [4'-0" x 2'-0"] plastic laminate countertop, with stainless steel kitchen sink. Provide
minimum 1219 mm of wall cabinets; mounted to provide 610 mm clearance above countertop
[verify with user that proposed coffee maker will fit in this space]. Provide dedicated electrical
receptacle for coffee maker (coffee maker not in contract).
Floor: porcelain tile, or ceramic tile.
Base: porcelain tile, or ceramic tile.
Walls: painted gypsum wallboard or painted veneer plaster.
Ceiling: suspended acoustical panel ceiling.
2-5.1.6.5 Other requirements:
2-5.2
S-1/PAC Section. Provide one group of offices.
S-1 Officer. Provide one; 8.8 m2 [95 sf]. Room shall be accessed through the
2-5.2.1
S-1/PAC Clerical/Central Files area. Occupants: 1, and occasional visitors.
2-5.2.1.1 Function: Private office for S-1 officer.
2-5.2.1.2 Adjacency requirements: Adjacent to S-1/PAC Clerical/Central Files. Near Command
Section offices.
2-5.2.1.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair, and one desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.2.1.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Room shall have exterior window. Partitions shall have minimum
STC rating of 55.
Office. Provide three; each 8.8 m2 [95 sf]. Area may be a private office or a
2-5.2.2
SOW-63