Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-5.2.4.2 Adjacency requirements: Adjacent to lobby/main corridor; adjacent to, and accessed
from, S-1/PAC Clerical /Central Files.
2-5.2.4.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one legal-size four-drawer file cabinet, one side chair, and one
desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.2.4.5 Other requirements: Provide 914 mm [3'-0"] wide door into room from S-1/PAC
Clerical Central Files area.; door shall have entry function (F81) lockset and glass vision panel.
Provide duty officer counter (built-in casework) minimum 1829 mm [6'-0"] long separating the
Duty Officer room from the lobby/corridor. The counter on the corridor side shall be minimum
1524 mm wide x 1016 mm high x 305 mm deep; provide locking overhead coiling shutter to
secure the opening when unattended; shutter hood shall not be visible from corridor side.
[modify requirement for sliding pass-through window above counter if requested by user].
Message Mail Center. Provide one; 19 m2 [205 sf]. Room shall be accessed from
2-5.2.5
the PAC Clerical/Central Files area. Occupants: [___].
2-5.2.5.1 Function: Mail sorting [add to description of function].
2-5.2.5.2 Adjacency requirements: Adjacent to corridor/lobby; adjacent to, and accessed from,
S-1/PAC Clerical/Central Files.
2-5.2.5.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate [insert
furniture requirements]
Base: resilient base, or porcelain tile base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.2.5.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset and glass vision panel. Provide counter (built-in casework)
minimum 1829 mm [6'-0"] long separating the Message Mail Center from the corridor. The
counter on the corridor side shall be minimum 1524 mm wide x 1016 mm high x 305 mm deep;
provide locking overhead coiling shutter to secure the opening when unattended; shutter hood
shall not be visible from corridor side [modify requirement for sliding pass-through window
above counter if requested by user].
2-5.2.6
Supply Room. Provide one; 12 m2 [130sf]. Room shall be under control of, and
located near, S-1/PAC Clerical/Central Files area. Room will be used by all administrative
sections; provide access from main corridor.
SOW-65