Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-5.5.1.2 Adjacency requirements: Adjacent to S-4 Clerical /Central Files.
2-5.5.1.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair, and one desk chair.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.5.1.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Room shall have exterior window. Partitions shall have minimum
STC rating of 55.
Office. Provide two; each 8.8 m2 [95 sf]. Area may be a private office or a systems
2-5.5.2
furniture workstation accessed through the S-4 Clerical/Central Files area. Occupants: 1 in
each office [verify with user].
2-5.5.2.1 Function: Private office or systems furniture workstation for use by S-4 personnel.
2-5.5.2.2 Adjacency requirements: Adjacent to S-4 Clerical /Central Files.
2-5.5.2.3 Furnishings/Fixtures/Equipment: Provide and design each area to accommodate one
desk [____] with return [____], one bookcase [___], two legal-size four-drawer file cabinets, one
side chair, and one desk chair. If systems furniture panels are provided in lieu of drywall
partitions, provide workstation type ___.
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.5.2.5 Other requirements: Exterior window is desirable. If drywall partitions are used,
provide 914 mm [3'-0"] wide door into each room; door shall have entry function (F81) lockset.
Drywall partitions shall have minimum STC rating of 49.
S-4 Clerical/Central Files. Provide one; 58 m2 [625 sf]. S-4 Clerical/Central Files
2-5.5.3
shall be accessed from the lobby or corridor. The area shall have direct access to S-4 private
offices. Occupants: 6 staff , and occasional visitors.
2-5.5.3.1 Function: Open office area for S-4 admin staff; access to S-4 offices.
2-5.5.3.2 Adjacency requirements: Adjacent to lobby or corridor. Adjacent to S-4 private
offices.
2-5.5.3.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate six type
___ systems furniture workstations.