Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
2-5.7.4.1 Function: storage closet for supplies used by soldier services functions.
2-5.7.4.2 Adjacency requirements: Adjacent to soldier services spaces and corridor.
2-5.7.4.3 Furnishings/Fixtures/Equipment: Provide [add shelving requirement].
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling, painted gypsum wallboard, or painted veneer
plaster.
2-5.7.4.5 Other requirements:
2-5.8
Brigade HQ Common Areas. Provide the following areas in each building.
Handicapped accessibility is required in all common areas except janitor closet and shower
rooms.
2-5.8.1
Lobby and Corridors. Provide as required to allow access to building spaces.
Unless otherwise required, minimum width of lobby/main corridor shall not be less than 3048
mm [10'-0"]; minimum width of other major corridors shall not be less than 1829 mm [6'-0"].
Corridor width shall comply with applicable egress codes.
2-5.8.1.1 Function: Entry to the facility; egress and circulation through the building.
2-5.8.1.2 Adjacency requirements: Adjacent to main entrances. It is preferable to enter
lobby/main corridor from two sides of the building.
2-5.8.1.3 Furnishings/Fixtures/Equipment: Provide wall mounted electric water cooler. Provide
mechanical and electrical systems to comply with applicable codes. Provide fire extinguishers
in semi-recessed fire extinguisher cabinets to comply with applicable codes. Provide recessed
space for one vending machine (machine is not in contract). Provide interior signage to identify
major spaces. Provide two recessed trophy cases (minimum size: 2438 mm wide x 1524 high x
406 mm deep); provide one recessed building directory near each main entrance. Provide one
1219 mm high x 1829 mm wide [4'-0" x 6'-0"] wall mounted bulletin board.
Floor: porcelain tile, vinyl composition tile, or carpet.
Base: porcelain tile, stained wood base, or resilient cove base.
Walls: painted gypsum wallboard, or painted veneer plaster.
Ceiling: suspended acoustical panel ceiling
2-5.8.1.5 Other requirements: Handicap accessible.
2-5.8.2
Entry Vestibules. Provide at each exterior entrance to lobby/main corridor area. [If
climate dictates, revise this sentence to require vestibules at all entrances to the building.]
2-5.8.1.1 Function: Primary entry point into the facility; weather protection for interior spaces.
2-5.8.1.2 Adjacency requirements: Adjacent to lobby/main corridor.
SOW-73