Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.5.3.5 Other requirements: Provide 914 mm [3'-0"] wide door into room; door shall have
entry function (F81) lockset. Exterior window is desirable. Partitions shall have minimum STC
rating of 49. Minimum ceiling height 2642 mm [8'-8"].
Conference Room. Provide one; 36 m2 [455 sf] Room shall be located to allow
2-5.6
direct access from the main corridor/lobby and the CO office. Occupants: up to 30 persons.
2-5.6.1
Function: Conference room for brigade leadership, staff, and visitors. Functions will
include staff meetings, hearings, disciplinary sessions, training.
2-5.6.2
Adjacency requirements: Adjacent to lobby or corridor; adjacent to CO office. Near
other administrative sections.
2-5.6.3
Furnishings/Fixtures/Equipment: Provide and design room to accommodate
[Coordinate furniture requirements with user]. Provide one marker board (minimum 2438 mm
wide x 1219 mm high [8'-0" x 4'-0"]) and one 2438 mm wide [8'-0"] wall mounted pull-down
projection screen.
2-5.6.4
Finishes:
Floor: carpet
Base: resilient base
Walls: painted gypsum wallboard or painted veneer plaster
Ceiling: suspended acoustical panel ceiling
2-5.6.5
Other requirements: Provide 914 mm [3'-0"] wide doors into room; doors shall have
classroom function (F84) lockset. Partitions shall have minimum STC rating of 55. Minimum
ceiling height 2642 mm [8'-8"].
2-5.7
Soldier Services. Provide one group of offices. Soldier services are unrelated to
other battalion administration functions; locate off of main lobby/corridor.
Chaplain's Assistant. Provide one; 7.9 m2 [85 sf]. Room shall be accessed from
2-5.7.1
the lobby or main corridor. Occupants: 1, and visitors.
2-5.7.1.1 Function: Private office for Chaplain's Assistant and waiting area for visitors to
Chaplain's office.
2-5.7.1.2 Adjacency requirements: Adjacent to lobby or main corridor.
2-5.7.1.3 Furnishings/Fixtures/Equipment: Provide and design room to accommodate one
desk [____] with return [____], one bookcase [___], two side chairs, and one desk chair.
Floor: carpet
Base: resilient base
SOW-71