Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
floor of the building. Toilet rooms will be accessed from corridors. Arrange entrance to provide
visual privacy.
2-4.10.3.1 Function: Restrooms for male occupants.
2-4.10.3.2 Adjacency requirements: Adjacent to corridor.
2-4.10.3.3 Furnishings/Fixtures/Equipment: Provide 3 lavatories, 4 floor mounted toilets, and 2
wall-hung urinals for each battalion. Lavatories in single-occupant toilet rooms shall be wall-
hung; lavatories in gang toilets shall be countertop mounted. Countertops shall be plastic
laminate or solid surfacing material. Provide toilet partitions at each toilet, and urinal partitions
between urinals. Provide the following toilet accessories: one mirror with shelf above each wall-
hung lavatory; one continuous mirror full width of countertop at countertop mounted lavatories;
one paper towel dispenser/waste receptacle per toilet room; one soap dispenser per lavatory;
one toilet tissue dispenser per toilet; one robe hook on each toilet partition door.
Floor: porcelain tile, or ceramic tile.
Base: porcelain tile, or ceramic tile.
Walls: ceramic tile, or 1829 mm high ceramic tile wainscot with painted impact resistant gypsum
wallboard or painted concrete masonry units above.
Ceiling: painted Portland cement plaster, or painted gypsum wallboard or veneer plaster.
2-4.10.3.5 Other requirements:
2-4.10.4 Women's Toilet Room(s). Provide one or more rooms, sized to accommodate the
number of plumbing fixtures required for each battalion served. In a two-story structure, one of
the required toilet fixtures and one of the required lavatories shall be provided in a single
occupant female toilet room on the second floor. If two battalion headquarters are combined in
one building, the required number of fixtures may be combined in one female toilet room on
each floor of the building. Toilet rooms will be accessed from corridors. Arrange entrance to
provide visual privacy.
2-4.10.4.1 Function: Restrooms for female occupants.
2-4.10.4.2 Adjacency requirements: Adjacent to corridor.
2-4.10.4.3 Furnishings/Fixtures/Equipment: Provide 4 lavatories and 4 floor mounted toilets for
each battalion. Lavatories in single-occupant toilet rooms shall be wall-hung; lavatories in gang
toilets shall be countertop mounted. Countertops shall be plastic laminate or solid surfacing
material. Provide toilet partitions at each toilet. Provide the following toilet accessories: one
mirror with shelf above each wall-hung lavatory; one continuous mirror full width of countertop at
countertop mounted lavatories; one paper towel dispenser/waste receptacle per toilet room; one
soap dispenser per lavatory; one toilet tissue dispenser per toilet; one sanitary napkin disposal
at each toilet; one robe hook on each toilet partition door.
Floor: porcelain tile, or ceramic tile.
Base: porcelain tile, or ceramic tile.
Walls: ceramic tile, or 1829 mm high ceramic tile wainscot with painted impact resistant gypsum
wallboard or painted concrete masonry units above.
SOW-56