Project Name
Project Number
UEPH Complex
Statement of Work
26 November 2001
Walls: Wire mesh partitions will separate NBC Storage area from Equipment Maintenance and
adjacent storage areas within the COF. Provide painted impact resistant gypsum wallboard, or
painted concrete masonry units at exterior walls and walls separating NBC Storage from
adjacent COFs.
Ceiling: painted exposed structure, or wire mesh.
2-3.2.5.5 Other requirements: Provide 914 mm [3'-0"] wide swinging door with keyed cylinder
lock in wire mesh partition at Equipment Storage. Provide wire mesh ceiling or extend wire
mesh partitions to underside of structure above.
Communications Storage.
Provide one area. Minimum area: Large company 15.8 m
2
2-3.2.6
[170 sf]; Medium company 14 m2 [150 sf]; Small company 11.15 m2 [120 sf]. Provide access from
Equipment Maintenance Area.
2-3.2.6.1 Function: Storage of radios and communications field gear.
2-3.2.6.2 Adjacency requirements: Adjacent to Equipment Maintenance Area.
2-3.2.6.3 Furnishings/Fixtures/Equipment: [add requirements for shelving].
Floor: sealed concrete
Base: resilient cove base
Walls: Wire mesh partitions will separate Communications Storage area from Equipment
Maintenance and adjacent storage areas within the COF. Provide painted impact resistant
gypsum wallboard, or painted concrete masonry units at exterior walls and walls separating
Communications Storage from adjacent COFs.
Ceiling: painted exposed structure, or wire mesh.
2-3.2.6.5 Other requirements: Provide 914 mm [3'-0"] wide swinging door with keyed cylinder
lock in wire mesh partition at Equipment Storage. Provide wire mesh ceiling or extend wire
mesh partitions to underside of structure above.
2-3.2.7
TA-50 Storage. Provide one area. Size and configure area to accommodate the
following quantity of TA-50 lockers per company (allow minimum 2438 mm [8'-0"] clearance
between parallel rows of lockers; minimum 914 mm [3'-0"] between open locker doors and
obstructions): Large company 96 lockers (approximately 136.4 m2 [1,468 sf]); Medium company
49 lockers (approximately 71.2 m2 [766 sf]; Small company 30 lockers (approximately 41.3 m2
[444 sf]). Provide access from Equipment Maintenance Area. Provide additional exit as
required by applicable codes.
2-3.2.7.1 Function: Gear lockers for storage of individual soldier's TA-50 field gear.
2-3.2.7.2 Adjacency requirements: Adjacent to Equipment Maintenance Area.
2-3.2.7.3 Furnishings/Fixtures/Equipment: Provide TA-50 gear lockers; refer to paragraph _____.
Floor: sealed concrete
Base: resilient cove base, or none.
Walls: Wire mesh partitions will separate TA-50 Storage area from Equipment Maintenance and
SOW-34